Compact Operating Instructions – DOP11C
4
Mounting the operator panel
Installation
4.3 Mounting the operator panel
How the operator panel is mounted depends on the unit type:
DOP11C-40, -70 and -100
Use all the retaining slots and the brackets and screws supplied to mount the
operator panel.
DOP11C-120 and DOP11C-150
Mount the operator panel to its designated spot using 8 screws (Torx, M4).
Loosen the screw [1] with a screw driver (Torx, TX7) [2] until the retaining clamp tilts
up. Then tighten the screw clockwise (0.4 Nm) until the retaining clamp is pressed
against the housing wall.
Repeat the procedure for the remaining screws.
4249326347 4249328011
8953957771
[1] Screw (Torx, M4)
[2] Screw driver (Torx, TX7)
[3] Retaining clamp
0.5 - 1.0 Nm
[1]
[2]
[3]
TX7